3. Instruction Set
3-67
API Mnemonic Operands Function
14
D CML P
Compliment
Controllers
ES2/EX2 SS2
SA2
SE
SX2
Bit Devices Word devices Program Steps Type
OP
X Y M S K H KnX KnY KnM KnS T C D E F
S
* ** * * * * * ***
D
* * * * * ***
CML, CMLP: 5 steps
DCML, DCMLP: 9 steps
PULSE 16-bit 32-bit
ES2/EX2 SS2
SA2
SE
SX2 ES2/EX2 SS2
SA2
SE
SX2 ES2/EX2 SS2
SA2
SE
SX2
Operands:
S: Source of data D: Destination device
Explanations:
1. The instruction reverses the bit pattern (01, 10) of all the contents in S and sends the
contents to D.
2. If operand S and D use index register F, only 16-bit instruction is available
Program example 1:
When X10 = ON, b0 ~ b3 in D1 will be inverted and sent to Y0 ~ Y3
X20
CML K1Y0D1
b0b1b2b3b15
D1
1
0
1
0
1
0
1
0
1
0
1
0
1
0
1
0
Symbol bit 0=positive, 1=negative) (
0
1
0
1
No variation Transfer data
Program example 2:
The diagram below can be substituted by the instruction on the right.
X000
M0
M1
M2
M3
X001
X002
X003
X000
M0
M1
M2
M3
X001
X002
X003
M1000
CML K1X0 K1M0
Normally ON contact