MS-250 Mixed Signal Oscilloscope Option
Displaying Digital Traces
The Trace On checkbox is selected by default, so if you are connected to a live input, you
should see digital traces appear as you add lines to the group.
To turn off the trace display, clear Trace On.
CAUTION. Do not use the All Lines Off or All Lines On buttons to control the display.
Doing so will erase your digital group set up. Use the Trace On checkbox to show or
hide the traces.
Position Traces
In Position, enter the number of divisions (positive or negative) relative to the zero line of
the grid where the display begins.The top of the first trace appears at this position.
In Line Height, enter the total number of grid divisions each line should occupy. The
selected traces (Line or Bus) will appear in this much space.
Individual traces are resized to fit the total number of divisions available. In the example
below, each trace takes up one division.
To move the entire group of traces to another grid, touch the Next Grid button at the bottom
right of the dialog.
NOTE: This button will only appear if your oscilloscope has this capability.
Change Trace Style
When Trace On is enabled, digital Line traces show the state of each line relative to the
threshold. You can also view a digital Bus trace that collapses all the lines in a group into
their Hex values. At the far right of the dialog, choose to either:
l Expand the group into individual line traces. The size and placement of the lines
depend on the number of lines, the Vertical Position and Line Height settings.
l Collapse the group into a single bus trace.
Digital line traces 1 division high starting at position 4 (top of grid).
16